MOQ: | 500M |
harga: | USD 0.4 To 10.5 per Meter |
standard packaging: | Baja Drum kayu |
Delivery period: | 10-15 hari |
Supply Capacity: | 5 KM per Hari |
Tipe | Nilai tegangan (KV) | Jumlah inti | Salib nominal | ||
Garis utama | Garis bumi | Garis kontrol | |||
SAYA | 0,38 / 0,66 | 3 | 1 | - | 4-185 |
MYP | 0,66 / 1,14 | 3 | 1 | - | 10-185 |
MYP | 1.9 / 3.3 | 3 | 1 | - | 16-185 |
MYP | 3.6 / 6 | 3 | 1 | - | 16-185 |
MYP | 6/10 | 3 | 1 | - | 16-185 |
MYP | 8.7 / 10 | 3 | 1 | - | 16-185 |
MC | 0,38 / 0,66 | 3 | 1 | 3-7 | 16-185 |
MCP | 0,66 / 1,14 | 3 | 1 | 3 | 35-185 |
MCP | 1.9 / 3.3 | 3 | 1 | 3 | 35-185 |
MCPT | 0,66 / 1,14 | 3 | 1 | 3 | 16-185 |
MCPT | 1.9 / 3.3 | 3 | 1 | 3 | 16-185 |
MYPT | 1.9 / 3.3 | 3 | 3 | - | 35-185 |
MYPT | 3.6 / 6 | 3 | 3 | - | 16-185 |
MYPT | 6/10 | 3 | 3 | - | 16-185 |
MYPT | 8.7 / 10 | 3 | 3 | 3 | 25-185 |
MZ | 0,3 / 0,5 | 3 | 1 | 1 | 2.5-4 |
MYQ | 0,3 / 0,5 | 2-12 | - | - | 1.0-6 |
Standar yang diterapkan
1 Untuk kabel pembakaran yang tidak menyebar, terapkan GB12972
2 Untuk kabel tahan api, implementasikan MT818
3 Untuk kabel penambangan khusus (dengan penampang lebih besar dan tegangan lebih tinggi), implementasikan
standar perusahaan.
CorexSize | Ketebalan nominal | Diameter keseluruhan (mm) MCPTJ-1.9 / 3.3 | ||||
Tahap | Landasan | Kontrol | Isolasi | Sarung | Min | Maks |
3x25 | 1x25 | 1x16 | 3 | 5.1 | 47.4 | 49.9 |
3x35 | 1x35 | 1x16 | 3 | 5.5 | 51.6 | 54.6 |
3x50 | 1x35 | 1x25 | 3 | 5.9 | 56.8 | 59.8 |
3x70 | 1x50 | 1x35 | 3 | 6.4 | 62.8 | 65.8 |
3x95 | 1x50 | 1x50 | 3 | 6.9 | 68.9 | 72.7 |
3x120 | 1x70 | 1x70 | 3 | 7.3 | 73.4 | 77.2 |
3x150 | 1x70 | 1x70 | 3 | 7.8 | 79 | 83.6 |
3x185 | 1x70 | 1x70 | 3 | 8 | 84.1 | 88.8 |
Tipe Inti | Ukuran nominal | Resistansi Insulasi Min pada 20 ℃ (MΩ.km) | |
Tidak lebih dari 0,66 / 1,14KV | 1.9 / 3.3KV | ||
Conducor fase atau Konduktor Asisten | 16 | 350 | 1150 |
25 | 300 | 980 | |
35 | 260 | 850 | |
50 | 230 | 740 | |
70 | 210 | 630 | |
95 | 200 | 550 | |
120 | 200 | 510 | |
150 | 180 | 450 | |
185 | 160 | 400 | |
Kontrol Konduktor | 4.6.10 | 100 | 100 |
MOQ: | 500M |
harga: | USD 0.4 To 10.5 per Meter |
standard packaging: | Baja Drum kayu |
Delivery period: | 10-15 hari |
Supply Capacity: | 5 KM per Hari |
Tipe | Nilai tegangan (KV) | Jumlah inti | Salib nominal | ||
Garis utama | Garis bumi | Garis kontrol | |||
SAYA | 0,38 / 0,66 | 3 | 1 | - | 4-185 |
MYP | 0,66 / 1,14 | 3 | 1 | - | 10-185 |
MYP | 1.9 / 3.3 | 3 | 1 | - | 16-185 |
MYP | 3.6 / 6 | 3 | 1 | - | 16-185 |
MYP | 6/10 | 3 | 1 | - | 16-185 |
MYP | 8.7 / 10 | 3 | 1 | - | 16-185 |
MC | 0,38 / 0,66 | 3 | 1 | 3-7 | 16-185 |
MCP | 0,66 / 1,14 | 3 | 1 | 3 | 35-185 |
MCP | 1.9 / 3.3 | 3 | 1 | 3 | 35-185 |
MCPT | 0,66 / 1,14 | 3 | 1 | 3 | 16-185 |
MCPT | 1.9 / 3.3 | 3 | 1 | 3 | 16-185 |
MYPT | 1.9 / 3.3 | 3 | 3 | - | 35-185 |
MYPT | 3.6 / 6 | 3 | 3 | - | 16-185 |
MYPT | 6/10 | 3 | 3 | - | 16-185 |
MYPT | 8.7 / 10 | 3 | 3 | 3 | 25-185 |
MZ | 0,3 / 0,5 | 3 | 1 | 1 | 2.5-4 |
MYQ | 0,3 / 0,5 | 2-12 | - | - | 1.0-6 |
Standar yang diterapkan
1 Untuk kabel pembakaran yang tidak menyebar, terapkan GB12972
2 Untuk kabel tahan api, implementasikan MT818
3 Untuk kabel penambangan khusus (dengan penampang lebih besar dan tegangan lebih tinggi), implementasikan
standar perusahaan.
CorexSize | Ketebalan nominal | Diameter keseluruhan (mm) MCPTJ-1.9 / 3.3 | ||||
Tahap | Landasan | Kontrol | Isolasi | Sarung | Min | Maks |
3x25 | 1x25 | 1x16 | 3 | 5.1 | 47.4 | 49.9 |
3x35 | 1x35 | 1x16 | 3 | 5.5 | 51.6 | 54.6 |
3x50 | 1x35 | 1x25 | 3 | 5.9 | 56.8 | 59.8 |
3x70 | 1x50 | 1x35 | 3 | 6.4 | 62.8 | 65.8 |
3x95 | 1x50 | 1x50 | 3 | 6.9 | 68.9 | 72.7 |
3x120 | 1x70 | 1x70 | 3 | 7.3 | 73.4 | 77.2 |
3x150 | 1x70 | 1x70 | 3 | 7.8 | 79 | 83.6 |
3x185 | 1x70 | 1x70 | 3 | 8 | 84.1 | 88.8 |
Tipe Inti | Ukuran nominal | Resistansi Insulasi Min pada 20 ℃ (MΩ.km) | |
Tidak lebih dari 0,66 / 1,14KV | 1.9 / 3.3KV | ||
Conducor fase atau Konduktor Asisten | 16 | 350 | 1150 |
25 | 300 | 980 | |
35 | 260 | 850 | |
50 | 230 | 740 | |
70 | 210 | 630 | |
95 | 200 | 550 | |
120 | 200 | 510 | |
150 | 180 | 450 | |
185 | 160 | 400 | |
Kontrol Konduktor | 4.6.10 | 100 | 100 |